      The overall structure design of the vehicle mounted mobiles substation is compact, with strong mobility, and can be put into use in a short time. It also has high power supply reliability, flexible operation, simple and convenient assembly, and each component can also be operated and transported separately. The semi trailer is usually in a mobiles standby state and can be dispatched upon receiving a departure command. It can be put into operation in the power grid within a few hours of reaching the designated destination, especially meeting the power supply needs of the high-voltage power grid power supply system in substation technical transformation, equipment maintenance, temporary power supply on construction sites, emergency repair, and natural disaster situations.
    Product technical features:
    1. Has 4 national patents, and the product technology is at the leading level in China;
    2. Rated voltage: 12-40.5kV;
    3. Transformer maximum capacity 20000kVA:
    4. Maximum rated short time withstand current of high-voltage cabinet: 40kA;
    5. Rated frequency: 50Hz;
    6. Protection level: IP55;
    7. The types of box structure include: prefabricated cabin structure, standard container structure, aluminum zinc coated anti-corrosion wood assembly structure, and GRC cement landscape structure;
    8. Product performance: suitable for mobiles power supply, with good flexibility, convenient power supply, and safe and reliable operation; 9. Mainly used in outdoor temporary electricity, military and other application scenarioses:
    10. Normal service life: 20 years;

    Voltage

    System voltage

    10kV.35kV

    High voltage side maximum workingvoltage

    12kV-40.5kV

    Low voltage side maximum working voltage

    0.66kV

        Bated frequenc

    50Hz

    High voltage

    switch cabinet

    1min powerfrequency withstand voltage (effective value)

    ≥42kV、≥95kV(relatively)

    4S Rated short-time withstand current

    25kA(effective value)

    Rated peak withstand current

    80kA

    Low voltage

    switch cabinet

    1min power frequency withstand voltage

    3kV

    Rated short-time withstand current

    40kA

    Rated peak withstand current

    100kA

    Protection level

    High yoltage switch cabinet housing

    lp55

    Low voltage switch cabinet housing

    p55